Failures | Reason | Shooting methods |
Suction pressure is too low | 1. Refrigerator load is too low 2. TXV(thermal expansion valve)is not open enough 3. The system has no enough refrigerattng fluid 4. TXV or fluid feed tube blockage or ice jam 5.The electromagnetic valve has blockage no enough opening | 1. Increase the load 2. Adjust the opening 3. Add more refrigerating fluid 4. Clear up the blockage 5.Remove the electromagnetic valve clean or exchange it |
Suction pressure is too high | Refrigerating fluid is too much TXV opened too much Heating load is big | Take out or recycle the refrigerating fluid Adjust the TXV Decrease the heating load |
Discharge pressure is too high | 1. Air enters the system 2. The cooling water cooling device is not enough 3. The system refrigerant charge too much 4. Cold suspect device furring result in reduced heat transfer | 1. Check excluded 2. Forced water cycle 3. Release or recycle from the system 4. Wash out dirt condenser |
Discharge pressure is too low | 1. 冷却水量(风量)过多 1. Cooling water (air volume) too much | 1. Reduce the amount of water (air volume) |
Discharge temperature is too high | 1. Exhaust temperature is too high 2.Inspiratory pressure is too low, the compression ratio increases 3. Inspiratory temperature is too large, evaporator less fluid | 1. After inspection excluded 2. Adjust the thermal expansion valve 3. Check excluded |
Suction temperature is too high | 1. Less refrigerant in the system 2. Thermal expansion valve opening degree is too small, less evaporator fluid supply | 1. Check after the increase 2. Adjust the thermal expansion valve |
Low-voltage relay early action | 1. Low-voltage renewal improper adjustment 2. Suction line valve above gas-liquid separator is not open 3. Solenoid valve damage can not open the solenoid valve power supply problem | 1. Re-adjustment 2. Open the valve 3. Repair and adjustment |
High-voltage relay early action | 1. Low-voltage renewal improper adjustment | 1. Re-adjustment |
Compressor shell too hot | 1. voltage is too low 2. Overload 3. The compressor short of oil 4. Motor fault | 1. Check the power supply 2. Check excluded 3. Check to refuel 4. Poor insulation inspection and repair |
Temperature relay early action | 1. No voltage 2. Milk tank temperature has to 3. Thermal power is not reset | 1. Check the line 2. Check the temperature controller is normal 3. Check the adjustment continued electrical appliances |
Refrigerating capacity is too low | 1. Refrigeration system lack of fluoride 2. Thermal expansion valve opening degree is too small, less evaporator fluid supply 3. Condensing temperature is too high | 1. Check add fluoride 2. Adjust 3. Check excluded |
The compressor shakes too much when working | 1. Stop oil heater is not open or failure, causing the lack of fluorine inside the compressor, the oil solubility increased 2.Compressor failure | 1. Check the oil heater to heat the compressor oil 2 Check exclusion |
Mixing motor gets hot | 1. Improper installation or agitator level uncorrected 2.Stirring wear sleeve, long interval | 1. Re-adjust the installation 2. Adjust the mixing sleeve |
Temperature is not right | 1. Temperature controller failure 2. Low-voltage renewal improper adjustment 3. Thermal breaker failure | 1. Measuring temperature probe is normal 2. Readjust 3. Check the adjustment continued electrical appliances |